People follow signs they can see, not routes they half-remember from induction. Fire exit and emergency signage is the cheapest life-safety system in your building – here is what it must include, where each sign goes, glow versus lit options for power cuts, and the maintenance routine that keeps it audit-ready.
Pillar: safety signs colours, shapes and placement. Service: safety signage printing.
What fire exit signs does a building need?
Every building needs directional exit signs at each corridor junction and turn, exit identifiers above every final exit door, floor and stairwell markings, assembly-point boards outside, and fire-equipment locators (extinguisher, hose reel, alarm call point, riser) visible from the approach path. Green running-man plus arrow combinations are the standard vocabulary – consistent arrows throughout, never mixed styles floor to floor. Multi-floor buildings add floor plans with “you are here” at lobbies and stair entries.
Glow-in-the-dark or electrically lit signs?
Electrically lit (LED edge-lit or illuminated) exit signs suit buildings with reliable backup power and maintained emergency circuits. Photoluminescent (glow-in-the-dark) signs charge from ambient light and glow through total power failure with no wiring – ideal for warehouses, stairwells and factories where circuits are the first casualty. Best practice in industrial Telangana sites is both: lit signs on mains-plus-backup circuits, photoluminescent low-level way-guidance strips that survive everything. Specify the glow duration grade (hours) when ordering – cheap boards fade in minutes.
Where exactly do exit signs go?
Above every exit door, at every corridor turn and junction, at every stair entry and floor landing, and repeated along long corridors so the next sign is always visible – plus assembly-point identification outside at the muster area. Mounting height follows the size and viewing-distance guide: too high and smoke hides them (which is why low-level floor-proximity strips matter), too low and racks block them. Walk every escape route quarterly with fresh eyes; stored pallets migrate to block signs within weeks.
How do I maintain emergency signage?
Monthly visual check (damage, fading, blocked sightlines), quarterly night or lights-off test of photoluminescent performance, annual review after layout changes (new racks, partitions, machinery), and immediate replacement after any fire drill finding. Log checks against audit requirements – a dated photo log beats memory in front of inspectors and insurers alike.
Who owns emergency signage in a building
Signage fails quietly. Nobody complains that the third-floor landing has no exit sign until there is smoke in the corridor. Give the work a named owner and a schedule, even in a small office.
| Role | Responsibility |
|---|---|
| Building owner or landlord | Base building escape routes, stairwells, common areas and the assembly point |
| Tenant or occupier | Signage inside the leased area, including fit-out changes and racking |
| Safety officer or facility manager | Monthly checks, the log, replacement orders and drill findings |
| Electrician | Wiring, emergency circuits, battery backup and the annual test |
| Signage supplier | Survey, sign schedule, correct grades, installation and spares |
In a multi-tenant building, the boundary is the most common gap. A tenant adds a partition and blocks a corridor sign that the landlord installed. Write the boundary into the lease and into the fire plan, then walk it once a year with both parties present.
The sign schedule by building type
A sign schedule is a simple list: location, sign type, size, material, mounting method, quantity. It turns a vague instruction into something a printer can quote and an installer can follow.
| Building | Minimum set | Additions worth planning |
|---|---|---|
| Small office, one floor | Exit above the final door, directional sign at the corridor turn, extinguisher locator, assembly point | Floor plan at the lift lobby, low-level strips on the main route |
| Clinic or salon | Exit signs on every route, extinguisher and alarm points, no-smoking, emergency contact board | Evacuation plan for clients, staff-only route markers, assembly point away from the entrance |
| Restaurant or cafe | Exit signs front and rear, kitchen extinguisher and blanket locators, gas shut-off marker | Low-level strips in the kitchen, signs in staff languages, assembly point clear of the gas bank |
| Factory or workshop | Exit signs at every bay and turn, machine hazard signs, first-aid and eyewash locators, muster board | Floor markings, vehicle route signs, trilingual boards, photoluminescent strips on every aisle |
| Warehouse | High-level exit signs over racking, aisle direction signs, extinguisher and hydrant locators | Low-level way guidance, signed refuges, signs that survive forklift traffic |
| Multi-floor office or hotel | Exit signs at every landing and stair entry, floor plans with you-are-here, stair identification | Floor-number signage inside the stairwell, photoluminescent handrail markers |
Walk the route from the furthest desk, the deepest rack and the last table in the restaurant. If you have to remember which way to turn, the route needs another sign.
Photoluminescent grades: what to specify
Glow signage is not one product. The grade decides how bright it is and how long it lasts after the lights fail.
- Glow duration: ask for the measured duration to a stated brightness, not a claim of hours. Cheap vinyl fades within minutes.
- Charge source: the material needs ambient light to charge. A stairwell with no working light will not charge a strip.
- Grade by location: low-level strips in stairs and corridors need a higher grade than a store-room door sign.
- Backing: rigid aluminium or composite for walls and doors, flexible strip for skirting, handrails and floor proximity.
- Adhesive: ordinary tape fails on dusty concrete and painted brick. Specify mechanical fixing or a proper mounting channel.
- Test certificate: ask for the test report with the batch, and keep it with the sign schedule.
A lights-off test once a quarter is the only proof that matters. Note the time, the person and the result, and replace anything that no longer reads from the normal walking position.
Installation details that decide whether signs work
- Mount exit signs above the door, on the approach side, so they are visible before the door is reached.
- Keep the sign clear of the door swing, the curtain, the shutter and the racking.
- Use consistent arrow directions along a route. A left arrow that becomes a right arrow at the next junction is worse than no sign.
- Repeat signs along long corridors. The rule is simple: the next sign should be visible from the one before it.
- Angle wall signs slightly into the approach where a flat mount would be seen edge-on.
- Do not mount on glass without a backing panel, or the sign disappears against the light.
- Keep the bottom of low-level strips clear of pallet trucks, mops and cleaning machines.
- Photograph every installation with the location noted, so the next fit-out can put it back correctly.
The audit log
An inspector or insurer will ask when the signage was last checked and what changed. One page per building is enough.
| Column | What to record |
|---|---|
| Date and time | When the check happened, including the lights-off test |
| Checker | Name and role, not only initials |
| Area | Floor, bay or route covered |
| Finding | Missing, damaged, faded, blocked, wrong direction |
| Action | Cleaned, remounted, replaced, added to order |
| Photo | Before and after where the finding is visual |
| Close date | When the fix was verified, with a signature |
Keep the log with the fire drill record and the extinguisher check. Three separate files is how a finding gets raised and never closed.
Common failures
- Signs installed for the original layout and never updated after a fit-out.
- Racking, stock or a notice board parked in front of an exit sign.
- Mixed sign styles floor to floor, so staff stop trusting any of them.
- Illuminated signs wired to a circuit with no backup, dead in the first power cut.
- Photoluminescent strips in a stairwell with no light to charge them.
- An assembly point sign that points at a spot now used for parking.
- Signs ordered without a schedule, so quantities are short at the far end of the building.
None of these are expensive to fix. They are expensive to discover during an inspection, a drill or an incident.
Fit-out and renovation checklist
- Get the new layout drawing before demolition starts.
- Mark every exit, turn, stair, extinguisher and first-aid point on the drawing.
- Check whether the new partitions change the escape route or the travel distance.
- Order signs with the schedule, including 10 percent spares for damage.
- Install before the area is handed over, not after the staff move in.
- Update the floor plans and the assembly point if either changed.
- Brief the team on the new route and run a drill within the month.
- Photograph the finished installation and file it with the schedule.
FAQs
Are stickers enough for fire exits? For low-risk small offices, quality photoluminescent stickers at correct positions can suffice. For factories, warehouses and public buildings, rigid or aluminium boards with proper illumination grades are the audit-safe choice.
What wording – English only? Symbols first (standard running man), with trilingual text where workforces need it – see bilingual signs.
Can DeskBees survey and supply? Yes – site walkthrough plus sign schedule plus supply and installation in Hyderabad. Contact us.